Three tesla magnetic resonance angiography with ultrashort echo time describes the arteries near the cerebral aneurysm with clip and the peripheral cerebral arteries
-
Received: ,
Accepted: ,
Abstract
Background:
The assessment of the clipped cerebral aneurysm and the cerebral arteries after the treatment of subarachnoid hemorrhage (SAH) is important to find aneurysm regrowth or postoperative cerebral vasospasm. Usually, contrast-enhanced computed tomography angiography is performed for the evaluation of the arteries, but it has side effects of contrast medium. Time-of-flight magnetic resonance angiography (MRA) is a fast and non-invasive method, but clip-induced artifact limits assessment of the artery in the vicinity of the clip. 1.5T MRA with ultrashort echo time (UTE) reduces metal artifact, but the obtained image is too rough to evaluate the aneurysm remnant, and the description range is too narrow to assess the cerebral vasospasm. We routinely use SIGNA Pioneer 3.0T (GE Healthcare Life Sciences, Buckinghamshire, England) and perform SILENT SCAN with UTE-MRA for the postoperative assessment of the clipped aneurysm and cerebral arteries for SAH patients treated by clipping. It has better image quality and describes arteries with a wide description range, so it possesses the potential to overcome the disadvantages of 1.5T UTE-MRA.Case Description:
We presented a representative SAH patient who postoperatively underwent 3.0T UTE- MRA after clipping. The artery near the clipped aneurysm was evaluated in detail, and the cerebral arteries were described from the main trunk to the peripheral parts with a wide description range, which enabled the assessment of cerebral vasospasm.Conclusion:
3.0T UTE-MRA may be helpful for the usual assessment of the arteries after clipping and cerebral vasospasm in the future.Keywords
IMAGE REPORT
Background
The assessment of the clipped cerebral aneurysm and the cerebral arteries after the treatment of subarachnoid hemorrhage (SAH) is important to find aneurysm regrowth or postoperative cerebral vasospasm. Of course, non-invasive methods are better for the assessment of the arteries after clipping. Usually, contrast-enhanced computed tomography angiography (CTA) is performed for the evaluation of clipped cerebral aneurysm[14] and the arteries, but it has side effects of contrast medium. Time-of-flight magnetic resonance angiography (TOF-MRA) is a fast and non-invasive method and used for evaluation of postoperative cerebral vasospasm, but clip-induced artifact limits assessment of the artery in the vicinity of the clip, especially of aneurysm neck remnants.[1] MRA with ultrashort echo time (UTE-MRA) reduces metal artifact,[3,7-9] and its usefulness is reported for the assessment of the internal flow in the intracranial stent,[4,10] moyamoya disease,[12] and arteriovenous malformation.[13] Besides, 1.5T UTE-MRA revealed the artery in the vicinity of a clip,[5] but the obtained image is too rough to evaluate the aneurysm remnant, and its description range is too narrow to assess the cerebral vasospasm especially of the peripheral portion. Therefore, 1.5T UTE-MRA does not yet have the clinically required quality as a usual follow-up after clipping.
3.0T UTE-MRA has a potential to overcome the problem which 1.5T UTE-MRA has because its image is not so rough, and its description range is wider. However, only Takubo et al. reported the usefulness of 3.0T UTE-MRA for the assessment of clipped aneurysm,[11] and they mainly investigated characteristic features of the artifacts derived from the clip. Therefore, the clinical usefulness of the 3.0T UTE-MRA, especially for SAH patients, has not been reported. We routinely use SIGNA Pioneer 3.0T (GE Healthcare Life Sciences, Buckinghamshire, England) and perform SILENT SCAN with UTE-MRA for the postoperative assessment of the aneurysm and cerebral arteries for SAH patients treated by clipping. SILENT SCAN can work as quiet as 3 dB and shorten the scan time without severe signal-noise-ratio reduction.[2] We herein presented a representative SAH patient who underwent 3.0T UTE-MRA. The artery near the clipped aneurysm was evaluated in detail, and the cerebral arteries were described from the main trunk to the peripheral parts with a wide description range, which enabled the assessment of cerebral vasospasm.
CASE DESCRIPTION
An 80-year-old woman developed SAH (Hunt and Konik Grade II) due to a ruptured aneurysm at the anterior communicating artery (ACoA). The preoperative CTA revealed the 4.0 mm aneurysm [arrowhead, Figure 1a] and the A1 portion of the anterior cerebral artery [arrow, Figure 1a] with a wide description range from the main trunk to the peripheral parts [Figure 1b]. We performed left frontotemporal craniotomy and clipping using the YASARGIL titanium clip (Aesculap, Tuttlingen, Germany). On the 5 postoperative day, 3.0T TOF-MRA did not describe the left A1 [arrow, Figure 1c], but 3.0T UTE-MRA described it [arrow, Figure 1d]. Both sequences described the cerebral arteries from the main trunk to the peripheral parts with a wide description range, which enabled the assessment of cerebral vasospasm [Figure 1e and f]. In addition, compared to the preoperative CTA [Figure 1g], postoperative 3.0T UTE-MRA revealed the arteries in the vicinity of the clip, the bilateral A1, A2 portions, and the ACoA, in detail [Figure 1h and i]. In the postoperative course, we confirmed no aneurysm regrowth nor postoperative cerebral vasospasm using 3.0T UTE-MRA, and the patient was discharged with a modified Rankin Scale score 0 on the 28th postoperative day.

DISCUSSION
This is the first report on the clinical usefulness of 3.0T UTE-MRA for postclipping assessment on the cerebral arteries. Compared to CTA, UTE-MRA is less invasive and fast, but its image quality is not up to the CTA. Compared to TOF-MRA, only UTE-MRA reveals the artery in the vicinity of a clip, but both sequences describe cerebral arteries from the main trunk to the peripheral parts. However, the total required time is longer in UTE-MRA than that in TOF-MRA because UTE-MRA needs arterial spin labeling (ASL) preparation,[8] multiple scans, and subtraction processing.[6] As another problem, the signal in UTE-MRA is weaker than that in TOF- MRA.[3] Furthermore, ASL may not always be performed if there is metal around the neck, such as an intubation tube cuff. Compared to 1.5T UTE-MRA, 3.0T UTE- MRA has the better image quality and wider description range, but the cost and the availability of the 3.0T MRI are problems.[6] In summary, 3.0T UTE-MRA can reduce the time and the invasiveness compared to CTA as well as overcome the disadvantages of 1.5T UTE-MRA, but it also has some disadvantages compared to the other sequences. In addition, the clip-induced metal artifact should be further investigated in 3.0T UTE-MRI,[11] and it should be clarified what kind of aneurysm, clip shape, and surgical procedure, like how to apply the clip, can be applied to 3.0T UTE-MRI. However, 3.0T UTE-MRI is helpful for the usual postoperative and outpatient assessment of the arteries after clipping and cerebral vasospasm in the future.
CONCLUSION
3.0T UTE-MRA may be helpful for the usual assessment of the arteries after clipping and cerebral vasospasm.
Declaration of patient consent
The authors certify that they have obtained all appropriate patient consent.Financial support and sponsorship
Nil.Conflicts of interest
There are no conflicts of interest.REFERENCES
- AJNR Am J Neuroradiol. 1988;9:885-9.MR imaging in patients with intracranial aneurysm clips.
- [Google Scholar]
- Available from: http://www3.gehealthcare.co.jp/ja-jp/products_and_service/imaging/magnetic_resonance_imaging/signa_pioneer [Last accessed on 2020 May 22]
- Neuroradiology. 2002;44:755-8.Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips.
- [Google Scholar]
- AJNR Am J Neuroradiol. 2015;36:967-70.Assessing blood flow in an intracranial stent: A feasibility study of MR angiography using a silent scan after stent-assisted coil embolization for anterior circulation aneurysms.
- [Google Scholar]
- Surg Neurol Int. 2020;11:65.Magnetic resonance angiography with ultrashort echo time evaluates cerebral aneurysm with clip.
- [Google Scholar]
- Nihon Hoshasen Gijutsu Gakkai Zasshi. 2018;74:1293-301.Imaging parameter optimization of 3D phase contrast-MRA to reduce susceptibility-artifact and radiofrequency-shielding around the intracranial stent.
- [Google Scholar]
- J Magn Reson Imaging. 2010;32:773-87.Magnetic resonance imaging near metal implants.
- [Google Scholar]
- J Comput Assist Tomogr. 2003;27:825-46.Magnetic resonance: An introduction to ultrashort TE (UTE) imaging.
- [Google Scholar]
- Radiology. 1990;175:861-65.Volume MR angiography: Methods to achieve very short echo times.
- [Google Scholar]
- Am J Neuroradiol. 2017;38:577-81.Usefulness of non-contrast-enhanced MR angiography using a silent scan for follow-up after Y-configuration stentassisted coil embolization for basilar tip aneurysms.
- [Google Scholar]
- Nihon Hoshasen Gijutsu Gakkai Zasshi. 2020;76:177-84.Clinical usefulness of ultra-short TE MRA for follow-up imaging after cerebral aneurysm clipping.
- [Google Scholar]
- Acta Radiol. 2019;60:1321-8.Comparison of TOF-MRA and silent scan-MRA in depicting cerebral arteries in patients with moyamoya disease.
- [Google Scholar]
- J Comput Assist Tomogr. 2019;43:943-7.Comparison of time-of-flight-magnetic resonance angiography from silent scan magnetic resonance angiography in depiction of arteriovenous malformation of the Brain.
- [Google Scholar]
- Neurosurgery. 1997;41:851-6.Postoperative spiral computed tomography and magnetic resonance angiography after aneurysm clipping with titanium clips.
- [Google Scholar]